Using Point-of-care Ultrasonography to Diagnose Traumatic Arthrotomy of the Knee: A Case Series

Abstract

Introduction: Accurate diagnosis of traumatic arthrotomy of the knee (TAK) is critical for patients presenting to the emergency department (ED) to ensure timely treatment. Current diagnostic modalities including plain radiography, computed tomography (CT), and the saline load test (SLT) have advantages and disadvantages. Point-of-care-ultrasonography (POCUS) offers a possible timely, low-cost, and efficient alternative method of diagnosing TAK. In this case series we present three cases where POCUS was used to diagnose TAK in the ED.

Case Series: Three patients in their early 20s presented to the ED complaining of knee trauma with wounds in proximity to the joint. Mechanisms of injury included a gunshot wound in one case and blunt trauma (motor vehicle collision and bicycle crash) in two cases. In all three cases TAK was suggested on POCUS examinations by the presence of intra-articular hyperechoic foci consistent with air artifact. All three cases had TAK confirmed by orthopedic evaluation.

Discussion: Ultrasound may have utility in the evaluation of patients presenting with knee trauma where TAK is a concern. The SLT is generally considered the gold standard test for diagnosis of TAK, but it is invasive and has a wide range of diagnostic accuracy. Intra-articular air has been found to be a sensitive marker for TAK in CT studies. Thus, additional investigations into the diagnostic accuracy of POCUS for this finding should be undertaken.

Main Content
For improved accessibility of PDF content, download the file to your device.
Current View